F3-NTP-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-COMPLIANCE, OBJECT-GROUP
             FROM SNMPv2-CONF
    MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, Unsigned32
             FROM SNMPv2-SMI                                           
    DisplayString, TruthValue, RowStatus, StorageType, VariablePointer,DateAndTime,
    TEXTUAL-CONVENTION
             FROM SNMPv2-TC
    neIndex, shelfIndex, slotIndex
             FROM  CM-ENTITY-MIB
    fsp150cm
             FROM  ADVA-MIB
    AdminState, OperationalState, SecondaryState, F3DisplayString,
    IpVersion, CmPmIntervalType, CmPmBinAction, PerfCounter64
             FROM  CM-COMMON-MIB
     CmNtpMode, CmNtpType 
             FROM CM-SYSTEM-MIB
    cmEthernetAccPortIndex, cmEthernetNetPortIndex
             FROM  CM-FACILITY-MIB
    Ipv6Address
             FROM  IPV6-TC;

f3NtpMIB MODULE-IDENTITY
    LAST-UPDATED    "202212260000Z"
    ORGANIZATION    "ADVA Optical Networking"
    CONTACT-INFO
        "Web URL: http://adva.com/
        E-mail:  support@adva.com
        Postal:  ADVA Optical Networking SE
             Campus Martinsried
             Fraunhoferstrasse 9a
             82152 Martinsried/Munich
             Germany
        Phone: +49 089 89 06 65 0
        Fax:  +49 089 89 06 65 199 "
    DESCRIPTION    "This module defines the NTP definitions used by
        the F3 (FSP150CM/CC) product lines.
        SNMP Tables in this module: f3NtpClockTable,f3NCITable,f3NtpVirtualPort,
               f3NtpRemoteClientTable,f3NtpAccPortFlowPointTable,
               f3NtpNetPortFlowPointTable,f3NCIStatsTable,
               f3NCIHistoryTable,f3NCIThresholdTable,
               f3NtpAccPortFlowPointStatsTable,f3NtpAccPortFlowPointHistoryTable,
               f3NtpAccPortFlowPointThresholdTable,
               f3NtpNetPortFlowPointStatsTable,f3NtpNetPortFlowPointHistoryTable,
               f3NtpNetPortFlowPointThresholdTable,
	       	   f3NtpTrackedClientTable, f3NtpTrackedClientStatsTable,
               f3NtpTrackedClientHistoryTable,f3NtpTrackedClientThresholdTable,
	       f3NtpRemoteServerTable.
        Copyright (C) ADVA."
    REVISION    "202208250000Z"
    DESCRIPTION
        " 
	Notes from release 202212260000Z
          a) Changed f3NtpClockOffset units to PerfCounter64
		
          Notes from release 202208250000Z
          a) Added new enum:
	  	NtpPollingInterval
	  	
          Notes from release 202208080000Z
          a) Added new table:
	  	f3NtpRemoteServer
	  
	  Notes from release 202208030000Z
          a) f3NtpClockEntry has new attributes:
	  	f3NtpClockOffset
		f3NtpClockSecondaryState

        Notes from release 202205190000Z
           a) added new tables to NCI:
           		f3NtpTrackedClientStatsTable
               f3NtpTrackedClientHistoryTable
               f3NtpTrackedClientThresholdTable    
          b) added new notification to NCI:
           		f3NtpTrackedClientCrossingAlert
          c) added new oid definition:
           		f3NtpPerformanceNotifications
           		
         Notes from release 202205090000Z
           a) added new table to NCI:
           		f3NtpTrackedClientTable              
        
          Notes from release 202204220000Z
           a) f3NCITable has new attributes:
                f3NCINtpHardenedResponderControl
         
          Notes from release 202204210000Z
           a) F3NCIStatsEntry has new attributes:
                f3NCIStatsAuthFailures 
                f3NCIStatsReqsDiscarded
                f3NCIStatsAvgTPS       
                f3NCIStatsMaxTPS   
                

           b) F3NCIHistoryEntry has new attributes:
                f3NCIHistoryAuthFailures  
                f3NCIHistoryReqsDiscarded 
                f3NCIHistoryAvgTPS        
                f3NCIHistoryMaxTPS          

          Notes from release 202103220000Z
          a)Added the literals local(3) and gps(4) to NtpTimeScale.
          b) added f3NCITimeScale and f3NCICurrentTimeOfDay scalar variable
          c) Change f3NtpClockTimeScale scalar variable to deprecated

          Notes from release 201912300000Z
           a) f3NCITable has new attributes:
                f3NtpAutokeyCtrl,

          Notes from release 201909260000Z
           a) f3NCITable has new attributes:
                f3NCIDaytimeServiceControl,
                f3NCITimeServiceControl
        
          Notes from release 201908260000Z
           a) New Textual Conventions : 
                           NtpAssociationMode
           b) f3NCITable has new attributes:
                           f3NCIAssociationMode,
                           f3NCIPeer1IpV4Address,
                           f3NCIPeer2IpV4Address,
                           f3NCIPeer3IpV4Address,
                           f3NCIPeer1IpV6Address,
                           f3NCIPeer2IpV6Address,
                           f3NCIPeer3IpV6Address,
                           f3NCIPeerMinInterval,
                           f3NCIPeerMaxInterval,
                           f3NCIPeerSymKeyIdList
                           
          Notes from release 201906270000Z
           a) New Textual Conventions : 
                           NtpBroadcastInterval and NtpVersion
           b) f3NCITable has new attributes:
                           f3NCIBroadcastState,
                           f3NCIBroadcastIpV4Address,
                           f3NCIBroadcastIpV6Address,
                           f3NCIBroadcastInterval,
                           f3NCIBroadcastMaxHops,
                           f3NCIBroadcastSymKeyId,
                           f3NCIBroadcastNtpVersion
                           
          Notes from release 201902040000Z
           a) f3NCITable has new attributes:
                           f3NCIDefaultGatewayControl

          Notes from release 201804280000Z
           a) f3NCITable has new attributes:
                           f3NCIIpV6UdpChecksum,
                           f3NCIIpV6Address,
                           f3NCIIpV6AddrPrefixLength,
                           f3NCIIpV4Gateway,
                           f3NCIIpV6Gateway
                           
          Notes from release 201610260000Z
           a) f3NtpRemoteClientTable has been changed:
                Attributes with Unsigned32 syntax:
                           f3NtpRemoteClientRxPacketsLo,
                           f3NtpRemoteClientRxPacketsHi,
                           f3NtpRemoteClientAvgPollIntervalLo,
                           f3NtpRemoteClientAvgPollIntervalHi,
                           f3NtpRemoteClientLastPollIntervalLo,
                           f3NtpRemoteClientLastPollIntervalHi
                 have been replaced by ones with PerfCounter64 syntax:
                           f3NtpRemoteClientRxPackets,
                           f3NtpRemoteClientAvgPollInterval,
                           f3NtpRemoteClientLastPollInterval
        
          Notes from release 201607120000Z
           First version."
    ::= {fsp150cm 47}

-- 
-- OID definitions
-- 
f3NtpObjects                OBJECT IDENTIFIER ::= {f3NtpMIB 1}
f3NtpConformance            OBJECT IDENTIFIER ::= {f3NtpMIB 2}
f3NtpPerformanceObjects    OBJECT IDENTIFIER ::= {f3NtpMIB 3}
f3NtpPerformanceNotifications  OBJECT IDENTIFIER ::= {f3NtpMIB 4}


-- 
-- Textual Conventions 
-- 
NtpFlowPointType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Enumerations for NTP Flow Point Type. Other enumeration values
            will be defined in the future. Presently only case is:
             server - represents a NTP Server Type."
    SYNTAX       INTEGER {
                   server(1)
                  }

NtpTimeScale ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for Time Scale,
        utc, not-available, local, gps."
    SYNTAX INTEGER    {
        utc(1),
        not-available(2),
        local(3),
        gps(4)        
        }

ToggleValue ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for functionality that can be enabled or disabled."
    SYNTAX INTEGER    {
        enabled(1),
        disabled(2),
        not-available(3)
        }

GnssSyncLossAction ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for specifying an action that a manager can execute."
    SYNTAX INTEGER    {
        strtm-16-li-nochg(1),
        strtm-16-li-unkn(2),
        strtm-1-li-unkn(3),
        none(4),
        not-available(5)
        }

NtpBroadcastInterval ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for NTP Broadcast Interval."
    SYNTAX INTEGER    {
        pkt1per8secs(1),
        pkt1per16secs(2),
        pkt1per32secs(3),
        pkt1per64secs(4),
        pkt1per128secs(5),
        pkt1per256secs(6),
        pkt1per512secs(7),
        pkt1per1024secs(8),
        pkt1per2048secs(9),
        pkt1per4096secs(10),
        pkt1per8192secs(11),
        pkt1per16384secs(12),
        pkt1per32768secs(13),
        pkt1per65536secs(14)
        }

NtpVersion ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for NTP Version."
    SYNTAX INTEGER    {
        ntpv3(1),
        ntpv4(2)
        }

NtpAssociationType ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for NTP Association Type."
    SYNTAX INTEGER    {
        not-available(1),
        symmetric-active(2),
        symmetric-passive(3),
        server-only(4)
        }
        
NtpPollingInterval ::= TEXTUAL-CONVENTION
    STATUS         current
    DESCRIPTION    "Enumerations for NTP Polling Interval."
    SYNTAX INTEGER    {
        sec16(1),
        sec32(2),
        sec64(3),
        sec128(4),
        sec256(5),
        sec512(6),
        sec1024(7)
        }

--
-- NTP Clock Table 
--
f3NtpClockTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpClockEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to the NTP Clock entities."
    ::= { f3NtpObjects 1 }

f3NtpClockEntry OBJECT-TYPE
    SYNTAX         F3NtpClockEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        NTP Clock entity."
    INDEX    { neIndex, f3NtpClockIndex }
    ::= { f3NtpClockTable 1 }

F3NtpClockEntry ::=
    SEQUENCE {
        f3NtpClockIndex Integer32,
        f3NtpClockAlias DisplayString,
        f3NtpClockAdminState AdminState,
        f3NtpClockOperationalState OperationalState,
        f3NtpClockTimeClock VariablePointer,
        f3NtpClockStratumLevel Unsigned32,
        f3NtpClockLeapIndicator Unsigned32,
        f3NtpClockTimeScale DisplayString,
        f3NtpClockPrecision Unsigned32,
        f3NtpClockRootDelay Unsigned32,
        f3NtpClockRootDispersion Unsigned32,
        f3NtpClockNtpMode CmNtpMode,
        f3NtpClockNtpType CmNtpType,
        f3NtpClockNtpAuthentication ToggleValue,
        f3NtpClockServerState ToggleValue,
        f3NtpClockTimeReferenceLossHandling GnssSyncLossAction,
        f3NtpClockRefClockId DisplayString,
        f3NtpClockStorageType   StorageType,
        f3NtpClockRowStatus     RowStatus,
        f3NtpAuthenticationSecureMode ToggleValue,
        f3NtpAutokeyCtrl              ToggleValue,
        f3NtpClockOffset              PerfCounter64,
	f3NtpClockSecondaryState      SecondaryState
   }


f3NtpClockIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the NTP Clock Entity."
    ::= { f3NtpClockEntry 1 }

f3NtpClockAlias OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..256))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide an
        alias to the NTP Clock entity."
    ::= { f3NtpClockEntry 2 }

f3NtpClockAdminState OBJECT-TYPE
    SYNTAX         AdminState
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the Administrative State of the NTP Clock."
    ::= { f3NtpClockEntry 3 }

f3NtpClockOperationalState OBJECT-TYPE
    SYNTAX         OperationalState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Operational State of the NTP Clock."
    ::= { f3NtpClockEntry 4 }

f3NtpClockTimeClock OBJECT-TYPE
    SYNTAX         VariablePointer
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object provides the entry from f3TimeClockTable, which is used as frequency and time of day source for the NTP Clock."
    ::= { f3NtpClockEntry 5 }

f3NtpClockStratumLevel OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The Ntp Stratum Level of the NTP Clock."
    ::= { f3NtpClockEntry 6 }

f3NtpClockLeapIndicator OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Leap Second indicator if a leap second will occur."
    ::= { f3NtpClockEntry 7 }

f3NtpClockTimeScale OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..16))
    MAX-ACCESS     read-only
    STATUS         deprecated
    DESCRIPTION    "Indicates whether the time source is UTC time or not."
    ::= { f3NtpClockEntry 8 }

f3NtpClockPrecision OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Todo."
    ::= { f3NtpClockEntry 9 }

f3NtpClockRootDelay OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Todo."
    ::= { f3NtpClockEntry 10 }

f3NtpClockRootDispersion OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Todo."
    ::= { f3NtpClockEntry 11 }

f3NtpClockNtpMode OBJECT-TYPE
    SYNTAX         CmNtpMode
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Indicates the current NTP mode of the NTP clock."
    ::= { f3NtpClockEntry 12 }

f3NtpClockNtpType OBJECT-TYPE
    SYNTAX         CmNtpType
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Todo."
    ::= { f3NtpClockEntry 13 }

f3NtpClockNtpAuthentication OBJECT-TYPE
    SYNTAX         ToggleValue
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Permits to enable or disable NTP Authentication."
    ::= { f3NtpClockEntry 14 }

f3NtpClockServerState OBJECT-TYPE
    SYNTAX         ToggleValue
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Permits to enable or disable the NTP Clock as Ntp Server."
    ::= { f3NtpClockEntry 15 }

f3NtpClockTimeReferenceLossHandling OBJECT-TYPE
    SYNTAX         GnssSyncLossAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Todo."
    ::= { f3NtpClockEntry 16 }

f3NtpClockRefClockId OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..4))
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object identifies the NTP Clock by a string."
    ::= { f3NtpClockEntry 17 }

f3NtpClockStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpClockEntry 18 }

f3NtpClockRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpClockRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpClockRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpClockRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpClockEntry 19 }

f3NtpAuthenticationSecureMode OBJECT-TYPE
    SYNTAX         ToggleValue
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows to enable or disable NTP Authentication Secure Mode."
    ::= { f3NtpClockEntry 20 }

f3NtpAutokeyCtrl OBJECT-TYPE
    SYNTAX         ToggleValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "Allows to enable or disable NTP Clock Server Auto Key."
    ::= { f3NtpClockEntry 21 }

f3NtpClockOffset OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This attribute indicates estimated time offset to the reference clock in ns"
    ::= { f3NtpClockEntry 22 }
    
f3NtpClockSecondaryState OBJECT-TYPE
    SYNTAX         SecondaryState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Secondary State of the NTP Clock."
    ::= { f3NtpClockEntry 23 }    
--
-- NTP Clock Interface Table 
--
f3NCITable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NCIEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to NTP Clock Interface (NCI) entities."
    ::= { f3NtpObjects 2 }

f3NCIEntry OBJECT-TYPE
    SYNTAX         F3NCIEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular NTP Clock Interface."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex }
    ::= { f3NCITable 1 }

F3NCIEntry ::=
    SEQUENCE {
        f3NCIIndex Integer32,
        f3NCIAlias DisplayString,
        f3NCIAdminState AdminState,
        f3NCIOperationalState OperationalState,
        f3NCIIfName DisplayString,
        f3NCIIpProtocol IpVersion,
        f3NCIIpV4Address IpAddress,
        f3NCIIpV4SubnetMask IpAddress,
        f3NCIDscp Unsigned32,
        f3NCIStorageType StorageType,
        f3NCIRowStatus RowStatus,
        f3NCIIpV6UdpChecksum ToggleValue,
        f3NCIIpV6Address Ipv6Address,
        f3NCIIpV6AddrPrefixLength Integer32,
        f3NCIIpV4Gateway IpAddress,
        f3NCIIpV6Gateway Ipv6Address,
        f3NCIDefaultGatewayControl  ToggleValue,
        f3NCIDaytimeServiceControl ToggleValue,
        f3NCITimeServiceControl ToggleValue,
        f3NCIBroadcastState  ToggleValue,
        f3NCIBroadcastIpV4Address  IpAddress,
        f3NCIBroadcastIpV6Address  Ipv6Address,
        f3NCIBroadcastInterval  NtpBroadcastInterval,
        f3NCIBroadcastMaxHops  Integer32,
        f3NCIBroadcastSymKeyId  Integer32,
        f3NCIBroadcastNtpVersion  NtpVersion,
        f3NCIAssociationMode NtpAssociationType,
        f3NCIPeer1IpV4Address IpAddress,
        f3NCIPeer2IpV4Address IpAddress,
        f3NCIPeer3IpV4Address IpAddress,
        f3NCIPeer1IpV6Address Ipv6Address,
        f3NCIPeer2IpV6Address Ipv6Address,
        f3NCIPeer3IpV6Address Ipv6Address,
        f3NCIPeerMinInterval NtpBroadcastInterval,
        f3NCIPeerMaxInterval NtpBroadcastInterval,
        f3NCIPeerSymKeyIdList DisplayString,
        f3NCITimeScale NtpTimeScale,
        f3NCICurrentTimeOfDay DateAndTime,
        f3NCINtpHardenedResponderControl ToggleValue
    }


f3NCIIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the NTP Clock Interface."
    ::= { f3NCIEntry 1 }

f3NCIAlias OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..256))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide an
        alias to the NTP Clock Interface entity."
    ::= { f3NCIEntry 2 }

f3NCIAdminState OBJECT-TYPE
    SYNTAX         AdminState
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the Administrative State of the NTP Clock Interface."
    ::= { f3NCIEntry 3 }

f3NCIOperationalState OBJECT-TYPE
    SYNTAX         OperationalState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Operational State of the NTP Clock Interface."
    ::= { f3NCIEntry 4 }

f3NCIIfName OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..15))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide a
        name to the NTP Clock Interface.  This is used for creation of the 
        underlying IP Interface associated with the NTP Clock Interface."
    ::= { f3NCIEntry 5 }

f3NCIIpProtocol OBJECT-TYPE
    SYNTAX         IpVersion
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the IP Protocol to communicate with associated NTP Clock."
    ::= { f3NCIEntry 6 }

f3NCIIpV4Address OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the IPv4 Address of the NTP Clock."
    ::= { f3NCIEntry 7 }

f3NCIIpV4SubnetMask OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the IPv4 Subnet Mask of the NTP Clock."
    ::= { f3NCIEntry 8 }

f3NCIDscp OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object represents Differenciated Services Code Point, its value is set into DS field in the IP header of IP packets."
    ::= { f3NCIEntry 9 }

f3NCIStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NCIEntry 10 }

f3NCIRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NCIRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NCIRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NCIRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NCIEntry 11 }

f3NCIIpV6UdpChecksum OBJECT-TYPE
    SYNTAX         ToggleValue 
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION
        "This object allows to enable/disable insertion of checksum on 
         transmit side of NTP packet and to ignore it on received side. 
         This object has an impact only on NTP Clock Interface with
         IPv6 address."
    ::= { f3NCIEntry 12 }

f3NCIIpV6Address OBJECT-TYPE
    SYNTAX         Ipv6Address 
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION
        "This object allows specification of the IPv6 Address of
         the NTP Clock Interface."
    ::= { f3NCIEntry 13 }

f3NCIIpV6AddrPrefixLength OBJECT-TYPE
    SYNTAX         Integer32 (0..128)
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION
        "This object allows specification of the IPv6 address prefix length of
         the NTP Clock Interface."
    ::= { f3NCIEntry 14 }

f3NCIIpV4Gateway OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION
        "This object allows to specify IPv4 gateway."
    ::= { f3NCIEntry 15 }

f3NCIIpV6Gateway OBJECT-TYPE
    SYNTAX         Ipv6Address
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION
        "This object allows to specify IPv6 gateway."
   ::= { f3NCIEntry 16 }

f3NCIDefaultGatewayControl OBJECT-TYPE
    SYNTAX     ToggleValue
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
         "This attribute controls Gateway address for NTP Clock Interface."
     ::= { f3NCIEntry 17 }

f3NCITimeServiceControl OBJECT-TYPE
    SYNTAX     ToggleValue
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
         "This attribute controls the Time service for NTP Clock Interface."
     ::= { f3NCIEntry 18 }
    
f3NCIDaytimeServiceControl OBJECT-TYPE
    SYNTAX     ToggleValue
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
         "This attribute controls the Daytime service for NTP Clock Interface."
     ::= { f3NCIEntry 19 }

f3NCIBroadcastState OBJECT-TYPE
    SYNTAX     ToggleValue
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object controls the use of NTP broadcasting."
     ::= { f3NCIEntry 20 }

f3NCIBroadcastIpV4Address OBJECT-TYPE
    SYNTAX     IpAddress
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Broadcast IPv4 Address of
         the NTP Clock Interface."
    ::= { f3NCIEntry 21 }

f3NCIBroadcastIpV6Address OBJECT-TYPE
    SYNTAX     Ipv6Address
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Broadcast IPv6 Address of
         the NTP Clock Interface."
    ::= { f3NCIEntry 22 }

f3NCIBroadcastInterval OBJECT-TYPE
    SYNTAX     NtpBroadcastInterval
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Broadcast Interval time of
          the NTP Clock Interface."
    ::= { f3NCIEntry 23 }

f3NCIBroadcastMaxHops OBJECT-TYPE
    SYNTAX     Integer32 (1..255)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Max of Hops for broadcasting
          of the NTP Clock Interface."
    ::= { f3NCIEntry 24 }

f3NCIBroadcastSymKeyId OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Symmetric key Id for
          broadcasting of the NTP Clock Interface."
    ::= { f3NCIEntry 25 }

f3NCIBroadcastNtpVersion OBJECT-TYPE
    SYNTAX     NtpVersion
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Ntp Version that is used
          for the NTP Clock Interface."
    ::= { f3NCIEntry 26 }

f3NCIAssociationMode OBJECT-TYPE
    SYNTAX     NtpAssociationType
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the Ntp Association Mode that is used
          for the NTP Clock Interface."
     ::= { f3NCIEntry 27 }

f3NCIPeer1IpV4Address OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    
         "IPv4 Address of the first peer of the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
          can be specified.
          But a maximum of three symmetric-passive peers can be specified per NTP Clock.
          If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
          associated and read, but they are not specified."
    ::= { f3NCIEntry 28 }

f3NCIPeer2IpV4Address OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    
         "IPv4 Address of the second peer of the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
          can be specified.
          But a maximum of three symmetric-passive peers can be specified per NTP Clock.
          If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
          associated and read, but they are not specified."
    ::= { f3NCIEntry 29 }

f3NCIPeer3IpV4Address OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    
         "IPv4 Address of the third peer of the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
          can be specified.
          But a maximum of three symmetric-passive peers can be specified per NTP Clock.
          If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
          associated and read, but they are not specified."
    ::= { f3NCIEntry 30 }

f3NCIPeer1IpV6Address OBJECT-TYPE
    SYNTAX         Ipv6Address
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    
         "IPv6 Address of the first peer of the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
          can be specified.
          But a maximum of three symmetric-passive peers can be specified per NTP Clock.
          If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
          associated and read, but they are not specified."
    ::= { f3NCIEntry 31 }

f3NCIPeer2IpV6Address OBJECT-TYPE
    SYNTAX         Ipv6Address
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    
         "IPv6 Address of the second peer of the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
          can be specified.
          But a maximum of three symmetric-passive peers can be specified per NTP Clock.
          If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
          associated and read, but they are not specified."
    ::= { f3NCIEntry 32 }

f3NCIPeer3IpV6Address OBJECT-TYPE
    SYNTAX         Ipv6Address
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    
         "IPv6 Address of the third peer of the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
          can be specified.
          But a maximum of three symmetric-passive peers can be specified per NTP Clock.
          If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
          associated and read, but they are not specified."
    ::= { f3NCIEntry 33 }

f3NCIPeerMinInterval OBJECT-TYPE
    SYNTAX     NtpBroadcastInterval
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the minimum of the peering Interval time of
          the NTP Clock Interface."
    ::= { f3NCIEntry 34 }

f3NCIPeerMaxInterval OBJECT-TYPE
    SYNTAX     NtpBroadcastInterval
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object allows specification of the maximum of the peering Interval time of
          the NTP Clock Interface."
    ::= { f3NCIEntry 35 }

f3NCIPeerSymKeyIdList OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "Symmetric key IDs for peering with the NTP Clock Interface.
          If NTP Association Mode is symmetric-active, then one key must be defined.
          If NTP Association Mode is symmetric-passive, up to 20 symmetric keys can be specified,
          each of them potentially matching the symmetric keys of a remote symmetric-active NCI."
    ::= { f3NCIEntry 36 }

f3NCITimeScale OBJECT-TYPE
    SYNTAX     NtpTimeScale
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
         "This attribute specifies Server time format."
    ::= { f3NCIEntry 37 }

f3NCICurrentTimeOfDay OBJECT-TYPE
    SYNTAX     DateAndTime
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "This attribute indicate the Current time of day provided by the NC."
    ::= { f3NCIEntry 38 }
    
f3NCINtpHardenedResponderControl OBJECT-TYPE
    SYNTAX     ToggleValue
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
         "This attribute controls the NTP Hardened Responder for NTP Clock Interface."
    ::= { f3NCIEntry 39 }

--
-- NTP Virtual Port Table 
--
f3NtpVirtualPortTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpVirtualPortEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to NtpVirtualPortEntry entities."
    ::= { f3NtpObjects 3 }

f3NtpVirtualPortEntry OBJECT-TYPE
    SYNTAX         F3NtpVirtualPortEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        NTP Virtual Port Entity."
    INDEX    { neIndex, shelfIndex, slotIndex, f3NtpVirtualPortIndex }
    ::= { f3NtpVirtualPortTable 1 }

F3NtpVirtualPortEntry ::=
    SEQUENCE {
        f3NtpVirtualPortIndex Integer32,
        f3NtpVirtualPortAlias DisplayString,
        f3NtpVirtualPortAdminState AdminState,
        f3NtpVirtualPortOperationalState OperationalState,
        f3NtpVirtualPortNtpFlowPoint VariablePointer,
        f3NtpVirtualPortStorageType   StorageType,
        f3NtpVirtualPortRowStatus     RowStatus
    }


f3NtpVirtualPortIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the NTP Virtual Port Entity."
    ::= { f3NtpVirtualPortEntry 1 }

f3NtpVirtualPortAlias OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..256))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide an
        alias to the NTP Virtual Port entity."
    ::= { f3NtpVirtualPortEntry 2 }

f3NtpVirtualPortAdminState OBJECT-TYPE
    SYNTAX         AdminState
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the Administrative State of the NTP Virtual Port
        Entity."
    ::= { f3NtpVirtualPortEntry 3 }

f3NtpVirtualPortOperationalState OBJECT-TYPE
    SYNTAX         OperationalState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Operational State of the NTP Virtual Port
        Entity."
    ::= { f3NtpVirtualPortEntry 4 }

f3NtpVirtualPortNtpFlowPoint OBJECT-TYPE
    SYNTAX         VariablePointer
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object associates the NTP Flow Point with the NTP Virtual Port."
    ::= { f3NtpVirtualPortEntry 5 }

f3NtpVirtualPortStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpVirtualPortEntry 6 }

f3NtpVirtualPortRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpVirtualPortRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpVirtualPortRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpVirtualPortRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpVirtualPortEntry 7 }

--
-- NTP Remote Client Table 
--
f3NtpRemoteClientTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpRemoteClientEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to NTP Remote Client entities."
    ::= { f3NtpObjects 4 }

f3NtpRemoteClientEntry OBJECT-TYPE
    SYNTAX         F3NtpRemoteClientEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        NTP Remote Client Entity."
    INDEX    { neIndex, shelfIndex, slotIndex, f3NtpRemoteClientIndex }
    ::= { f3NtpRemoteClientTable 1 }

F3NtpRemoteClientEntry ::=
    SEQUENCE {
        f3NtpRemoteClientIndex Integer32,
        f3NtpRemoteClientIpV4Address IpAddress,
        f3NtpRemoteClientRxPackets PerfCounter64,
        f3NtpRemoteClientAvgPollInterval PerfCounter64,
        f3NtpRemoteClientLastPollInterval PerfCounter64,
        f3NtpRemoteClientNtpMode Integer32,
        f3NtpRemoteClientNtpVersion Integer32,
        f3NtpRemoteClientStorageType   StorageType,
        f3NtpRemoteClientRowStatus     RowStatus
    }


f3NtpRemoteClientIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the NTP Remote Client Entity."
    ::= { f3NtpRemoteClientEntry 1 }

f3NtpRemoteClientIpV4Address OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object indicates the IPv4 Address of the NTP Remote Client."
    ::= { f3NtpRemoteClientEntry 2 }

f3NtpRemoteClientRxPackets OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the number of NTP packets sent by the NTP Remote Client and received on the NTP Flow Point."
    ::= { f3NtpRemoteClientEntry 3 }

f3NtpRemoteClientAvgPollInterval OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the interval over which monitored value has been the most recently sampled on the NTP Flow Point."
    ::= { f3NtpRemoteClientEntry 4 }

f3NtpRemoteClientLastPollInterval OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the interval over which monitored value is sampled and averaged on the NTP Flow Point."
    ::= { f3NtpRemoteClientEntry 5 }

f3NtpRemoteClientNtpMode OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the NTP Mode of the NTP Remote Client."
    ::= { f3NtpRemoteClientEntry 6 }

f3NtpRemoteClientNtpVersion OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the NTP protocol Version used by the NTP Remote Client to communicate with the NTP Server."
    ::= { f3NtpRemoteClientEntry 7 }

f3NtpRemoteClientStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpRemoteClientEntry 8 }

f3NtpRemoteClientRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpRemoteClientRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpRemoteClientRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpRemoteClientRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpRemoteClientEntry 9 }

--
-- Ethernet Access Port - NTP Flow Point Table 
--
f3NtpAccPortFlowPointTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpAccPortFlowPointEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to the Access Port 
        NTP Flow Point entities."
    ::= { f3NtpObjects 5 }

f3NtpAccPortFlowPointEntry OBJECT-TYPE
    SYNTAX         F3NtpAccPortFlowPointEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        Access Port NTP Flow Point Entity."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
        f3NtpAccPortFlowPointIndex }
    ::= { f3NtpAccPortFlowPointTable 1 }

F3NtpAccPortFlowPointEntry ::=
    SEQUENCE {
        f3NtpAccPortFlowPointIndex Integer32,
        f3NtpAccPortFlowPointAlias DisplayString,
        f3NtpAccPortFlowPointAdminState AdminState,
        f3NtpAccPortFlowPointOperationalState OperationalState,
        f3NtpAccPortFlowPointType NtpFlowPointType,
        f3NtpAccPortFlowPointOuterVlanEtherType Integer32,
        f3NtpAccPortFlowPointOuterVlanMemberList DisplayString,
        f3NtpAccPortFlowPointOuterUntaggedEnabled TruthValue,
        f3NtpAccPortFlowPointInner1VlanEtherType Integer32,
        f3NtpAccPortFlowPointInner1VlanMemberList DisplayString,
        f3NtpAccPortFlowPointInner1UntaggedEnabled TruthValue,
        f3NtpAccPortFlowPointInner2VlanEtherType Integer32,
        f3NtpAccPortFlowPointInner2VlanMemberList DisplayString,
        f3NtpAccPortFlowPointInner2UntaggedEnabled TruthValue,
        f3NtpAccPortFlowPointCOS Integer32,
        f3NtpAccPortFlowPointCIRLo Unsigned32,
        f3NtpAccPortFlowPointCIRHi Unsigned32,
        f3NtpAccPortFlowPointEIRLo Unsigned32,
        f3NtpAccPortFlowPointEIRHi Unsigned32,
        f3NtpAccPortFlowPointBufferSize Unsigned32,
        f3NtpAccPortFlowPointStorageType StorageType,
        f3NtpAccPortFlowPointRowStatus RowStatus
    }


f3NtpAccPortFlowPointIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the Access Port NTP Flow Point."
    ::= { f3NtpAccPortFlowPointEntry 1 }

f3NtpAccPortFlowPointAlias OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..256))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide an
        alias to the Access Port NTP Flow Point."
    ::= { f3NtpAccPortFlowPointEntry 2 }

f3NtpAccPortFlowPointAdminState OBJECT-TYPE
    SYNTAX         AdminState
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the Administrative State of the
        NTP Flow Point."
    ::= { f3NtpAccPortFlowPointEntry 3 }

f3NtpAccPortFlowPointOperationalState OBJECT-TYPE
    SYNTAX         OperationalState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Operational State of the NTP Flow
        Point."
    ::= { f3NtpAccPortFlowPointEntry 4 }

f3NtpAccPortFlowPointType OBJECT-TYPE
    SYNTAX         NtpFlowPointType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object represents the NTP Flow Point Type, i.e. whether
        it is for a NTP Server or a NTP Client. Note that only Server Type is
        available in this MIB Version."
    ::= { f3NtpAccPortFlowPointEntry 5 }

f3NtpAccPortFlowPointOuterVlanEtherType OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Outer VLAN Ether Type
        of the NTP Flow."
    ::= { f3NtpAccPortFlowPointEntry 6 }

f3NtpAccPortFlowPointOuterVlanMemberList OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Outer VLAN(s)
        of the NTP Flow."
    ::= { f3NtpAccPortFlowPointEntry 7 }

f3NtpAccPortFlowPointOuterUntaggedEnabled OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of whether the Outer VLAN
        exists or not."
    ::= { f3NtpAccPortFlowPointEntry 8 }

f3NtpAccPortFlowPointInner1VlanEtherType OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner1 VLAN Ether Type
        of the NTP Flow."
    ::= { f3NtpAccPortFlowPointEntry 9 }

f3NtpAccPortFlowPointInner1VlanMemberList OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner1 VLAN(s)
        of the NTP Flow."
    ::= { f3NtpAccPortFlowPointEntry 10 }

f3NtpAccPortFlowPointInner1UntaggedEnabled OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of whether the Inner1 VLAN
        exists or not."
    ::= { f3NtpAccPortFlowPointEntry 11 }

f3NtpAccPortFlowPointInner2VlanEtherType OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner2 VLAN Ether Type
        of the NTP Flow."
    ::= { f3NtpAccPortFlowPointEntry 12 }

f3NtpAccPortFlowPointInner2VlanMemberList OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner2 VLAN(s)
        of the NTP Flow."
    ::= { f3NtpAccPortFlowPointEntry 13 }

f3NtpAccPortFlowPointInner2UntaggedEnabled OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of whether the Inner2 VLAN
        exists or not."
    ::= { f3NtpAccPortFlowPointEntry 14 }

f3NtpAccPortFlowPointCOS OBJECT-TYPE
    SYNTAX         Integer32 (0..7)
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Class of Service of the traffic
        associated with this NTP Flow Point."
    ::= { f3NtpAccPortFlowPointEntry 15 }

f3NtpAccPortFlowPointCIRLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Committed Information Rate of the
        traffic associated with this NTP Flow Point.
        The CIR value is in bits-per-second units. The value of this object
        represents the lower 32 bits of the total CIR value."
    ::= { f3NtpAccPortFlowPointEntry 16 }

f3NtpAccPortFlowPointCIRHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Committed Information Rate of the
        traffic associated with this NTP Flow Point.
        The CIR value is in bits-per-second units. The value of this object
        represents the higher 32 bits of the total CIR value."
    ::= { f3NtpAccPortFlowPointEntry 17 }

f3NtpAccPortFlowPointEIRLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Excess Information Rate of the
        traffic associated with this NTP Flow Point.
        The EIR value is in bits-per-second units. The value of this object
        represents the lower 32 bits of the total EIR value."
    ::= { f3NtpAccPortFlowPointEntry 18 }

f3NtpAccPortFlowPointEIRHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Excess Information Rate of the
        traffic associated with this NTP Flow Point.
        The EIR value is in bits-per-second units. The value of this object
        represents the higher 32 bits of the total EIR value."
    ::= { f3NtpAccPortFlowPointEntry 19 }

f3NtpAccPortFlowPointBufferSize OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Buffer Size of the queue associated
        with this NTP Flow Point."
    ::= { f3NtpAccPortFlowPointEntry 20 }

f3NtpAccPortFlowPointStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpAccPortFlowPointEntry 21 }

f3NtpAccPortFlowPointRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpAccPortFlowPointRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpAccPortFlowPointRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpAccPortFlowPointRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpAccPortFlowPointEntry 22 }

--
-- Ethernet Network Port - NTP Flow Point Table 
--
f3NtpNetPortFlowPointTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpNetPortFlowPointEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to the Network Port 
        NTP Flow Point entities."
    ::= { f3NtpObjects 6 }

f3NtpNetPortFlowPointEntry OBJECT-TYPE
    SYNTAX         F3NtpNetPortFlowPointEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        Network Port NTP Flow Point Entity."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
        f3NtpNetPortFlowPointIndex }
    ::= { f3NtpNetPortFlowPointTable 1 }

F3NtpNetPortFlowPointEntry ::=
    SEQUENCE {
        f3NtpNetPortFlowPointIndex Integer32,
        f3NtpNetPortFlowPointAlias DisplayString,
        f3NtpNetPortFlowPointAdminState AdminState,
        f3NtpNetPortFlowPointOperationalState OperationalState,
        f3NtpNetPortFlowPointType NtpFlowPointType,
        f3NtpNetPortFlowPointOuterVlanEtherType Integer32,
        f3NtpNetPortFlowPointOuterVlanMemberList DisplayString,
        f3NtpNetPortFlowPointOuterUntaggedEnabled TruthValue,
        f3NtpNetPortFlowPointInner1VlanEtherType Integer32,
        f3NtpNetPortFlowPointInner1VlanMemberList DisplayString,
        f3NtpNetPortFlowPointInner1UntaggedEnabled TruthValue,
        f3NtpNetPortFlowPointInner2VlanEtherType Integer32,
        f3NtpNetPortFlowPointInner2VlanMemberList DisplayString,
        f3NtpNetPortFlowPointInner2UntaggedEnabled TruthValue,
        f3NtpNetPortFlowPointCOS Integer32,
        f3NtpNetPortFlowPointCIRLo Unsigned32,
        f3NtpNetPortFlowPointCIRHi Unsigned32,
        f3NtpNetPortFlowPointEIRLo Unsigned32,
        f3NtpNetPortFlowPointEIRHi Unsigned32,
        f3NtpNetPortFlowPointBufferSize Unsigned32,
        f3NtpNetPortFlowPointStorageType StorageType,
        f3NtpNetPortFlowPointRowStatus RowStatus
    }


f3NtpNetPortFlowPointIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the Network Port 
        NTP Flow Point."
    ::= { f3NtpNetPortFlowPointEntry 1 }

f3NtpNetPortFlowPointAlias OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..256))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide an
        alias to the Network Port NTP Flow Point."
    ::= { f3NtpNetPortFlowPointEntry 2 }

f3NtpNetPortFlowPointAdminState OBJECT-TYPE
    SYNTAX         AdminState
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the Administrative State of the
        NTP Flow Point."
    ::= { f3NtpNetPortFlowPointEntry 3 }

f3NtpNetPortFlowPointOperationalState OBJECT-TYPE
    SYNTAX         OperationalState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Operational State of the NTP Flow
        Point."
    ::= { f3NtpNetPortFlowPointEntry 4 }

f3NtpNetPortFlowPointType OBJECT-TYPE
    SYNTAX         NtpFlowPointType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object represents the NTP Flow Point Type, i.e. whether
        it is for a NTP Server or a NTP Client. Note that only Server Type is
        available in this MIB Version."
    ::= { f3NtpNetPortFlowPointEntry 5 }

f3NtpNetPortFlowPointOuterVlanEtherType OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Outer VLAN Ether Type
        of the NTP Flow."
    ::= { f3NtpNetPortFlowPointEntry 6 }

f3NtpNetPortFlowPointOuterVlanMemberList OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Outer VLAN(s)
        of the NTP Flow."
    ::= { f3NtpNetPortFlowPointEntry 7 }

f3NtpNetPortFlowPointOuterUntaggedEnabled OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of whether the Outer VLAN
        exists or not."
    ::= { f3NtpNetPortFlowPointEntry 8 }

f3NtpNetPortFlowPointInner1VlanEtherType OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner1 VLAN Ether Type
        of the NTP Flow."
    ::= { f3NtpNetPortFlowPointEntry 9 }

f3NtpNetPortFlowPointInner1VlanMemberList OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner1 VLAN(s)
        of the NTP Flow."
    ::= { f3NtpNetPortFlowPointEntry 10 }

f3NtpNetPortFlowPointInner1UntaggedEnabled OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of whether the Inner1 VLAN
        exists or not."
    ::= { f3NtpNetPortFlowPointEntry 11 }

f3NtpNetPortFlowPointInner2VlanEtherType OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner2 VLAN Ether Type
        of the NTP Flow."
    ::= { f3NtpNetPortFlowPointEntry 12 }

f3NtpNetPortFlowPointInner2VlanMemberList OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Inner2 VLAN(s)
        of the NTP Flow."
    ::= { f3NtpNetPortFlowPointEntry 13 }

f3NtpNetPortFlowPointInner2UntaggedEnabled OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of whether the Inner2 VLAN
        exists or not."
    ::= { f3NtpNetPortFlowPointEntry 14 }

f3NtpNetPortFlowPointCOS OBJECT-TYPE
    SYNTAX         Integer32 (0..7)
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Class of Service of the traffic
        associated with this NTP Flow Point."
    ::= { f3NtpNetPortFlowPointEntry 15 }

f3NtpNetPortFlowPointCIRLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Committed Information Rate of the
        NTP traffic associated with this Flow Point.
        The CIR value is in bits-per-second units. The value of this object
        represents the lower 32 bits of the total CIR value."
    ::= { f3NtpNetPortFlowPointEntry 16 }

f3NtpNetPortFlowPointCIRHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Committed Information Rate of the
        traffic associated with this NTP Flow Point.
        The CIR value is in bits-per-second units. The value of this object
        represents the higher 32 bits of the total CIR value."
    ::= { f3NtpNetPortFlowPointEntry 17 }

f3NtpNetPortFlowPointEIRLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Excess Information Rate of the
        traffic associated with this NTP Flow Point.
        The EIR value is in bits-per-second units. The value of this object
        represents the lower 32 bits of the total EIR value."
    ::= { f3NtpNetPortFlowPointEntry 18 }

f3NtpNetPortFlowPointEIRHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of Excess Information Rate of the
        traffic associated with this NTP Flow Point.
        The EIR value is in bits-per-second units. The value of this object
        represents the higher 32 bits of the total EIR value."
    ::= { f3NtpNetPortFlowPointEntry 19 }

f3NtpNetPortFlowPointBufferSize OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows specification of the Buffer Size of the queue associated
        with this NTP Flow Point."
    ::= { f3NtpNetPortFlowPointEntry 20 }

f3NtpNetPortFlowPointStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpNetPortFlowPointEntry 21 }

f3NtpNetPortFlowPointRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpNetPortFlowPointRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpNetPortFlowPointRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpNetPortFlowPointRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpNetPortFlowPointEntry 22 }

--
-- NTP Tracked Client Table 
--
f3NtpTrackedClientTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpTrackedClientEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to NTP Tracked Client entities."
    ::= { f3NtpObjects 7 }

f3NtpTrackedClientEntry OBJECT-TYPE
    SYNTAX         F3NtpTrackedClientEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        NTP Tracked Client Entity."
    INDEX    { neIndex, shelfIndex, slotIndex, f3NtpTrackedClientIndex }
    ::= { f3NtpTrackedClientTable 1 }

F3NtpTrackedClientEntry ::=
    SEQUENCE {
        f3NtpTrackedClientIndex 		Integer32,
        f3NtpTrackedClientAlias       	DisplayString,
        f3NtpTrackedClientIpV4Address 	IpAddress,
        f3NtpTrackedClientIpV6Address   Ipv6Address,             
        f3NtpTrackedClientStorageType   StorageType,
        f3NtpTrackedClientRowStatus     RowStatus
    }


f3NtpTrackedClientIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the NTP Tracked Client Entity."
    ::= { f3NtpTrackedClientEntry 1 }

f3NtpTrackedClientAlias    OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..256))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
         "This object allows SNMP management entities to provide an 
          alias to the Tracked Client."
     ::= { f3NtpTrackedClientEntry 2 }
     
f3NtpTrackedClientIpV4Address OBJECT-TYPE
    SYNTAX         IpAddress
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object indicates the IPv4 Address of the NTP Tracked Client."
    ::= { f3NtpTrackedClientEntry 3 }

f3NtpTrackedClientIpV6Address OBJECT-TYPE
    SYNTAX     Ipv6Address 
    MAX-ACCESS read-create
    STATUS   current
    DESCRIPTION
         "This object allows specification of the unicast IPv6 Address of
          the Tracked Client."
    ::= { f3NtpTrackedClientEntry 4 }


f3NtpTrackedClientStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpTrackedClientEntry 5 }

f3NtpTrackedClientRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpTrackedClientRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpRemoteClientRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpTrackedClientRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpTrackedClientEntry 6 }


--
-- NTP Remote Server Table 
--
f3NtpRemoteServerTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpRemoteServerEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A list of entries corresponding to NTP Server entities."
    ::= { f3NtpObjects 8 }

f3NtpRemoteServerEntry OBJECT-TYPE
    SYNTAX         F3NtpRemoteServerEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An entry containing information applicable to a particular
        NTP Remote Server Entity."
    INDEX    { neIndex, f3NtpClockIndex, f3NtpRemoteServerIndex }
    ::= { f3NtpRemoteServerTable 1 }

F3NtpRemoteServerEntry ::=
    SEQUENCE {

       f3NtpRemoteServerIndex Integer32,
       f3NtpRemoteServerAlias DisplayString,
       f3NtpRemoteServerAdminState AdminState,
       f3NtpRemoteServerOperationalState OperationalState,
       f3NtpRemoteServerSecondaryState SecondaryState,
       f3NtpRemoteServerServerAddress DisplayString,
       f3NtpRemoteServerMinPollInterval NtpPollingInterval,
       f3NtpRemoteServerMaxPollInterval NtpPollingInterval,
       f3NtpRemoteServerPreferred ToggleValue,
       f3NtpRemoteServerReach Unsigned32,                                      
       f3NtpRemoteServerStorageType StorageType,
       f3NtpRemoteServerRowStatus RowStatus

    }

f3NtpRemoteServerIndex OBJECT-TYPE
    SYNTAX         Integer32
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "Unique index value associated with the NTP Remote Server Entity."
    ::= { f3NtpRemoteServerEntry 1 }
    
f3NtpRemoteServerAlias OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..256))
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "This object allows SNMP management entities to provide an
        alias to the NTP Remote Server."
    ::= { f3NtpRemoteServerEntry 2 }

f3NtpRemoteServerAdminState OBJECT-TYPE
    SYNTAX         AdminState
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the Administrative State of the NTP Remote Server"
    ::= { f3NtpRemoteServerEntry 3 }

f3NtpRemoteServerOperationalState OBJECT-TYPE
    SYNTAX         OperationalState
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object represents the Operational State of the NTP Remote Server."
    ::= { f3NtpRemoteServerEntry 4 }
    
f3NtpRemoteServerSecondaryState OBJECT-TYPE
    SYNTAX      SecondaryState 
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "This object represents the Secondary State of the NTP Remote Server."
    ::= { f3NtpRemoteServerEntry 5 }
    
f3NtpRemoteServerServerAddress OBJECT-TYPE
    SYNTAX         DisplayString
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object specifies the NTP Remote Server Address in form of IPv4 or IPv6 address or hostname."
    ::= { f3NtpRemoteServerEntry 6 }

f3NtpRemoteServerMinPollInterval OBJECT-TYPE
    SYNTAX         NtpPollingInterval
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the specifies minimum polling interval on NTP Remote Server."
    ::= { f3NtpRemoteServerEntry 7 }

f3NtpRemoteServerMaxPollInterval OBJECT-TYPE
    SYNTAX         NtpPollingInterval
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object represents the specifies maximum polling interval on NTP Remote Server."
    ::= { f3NtpRemoteServerEntry 8 }

f3NtpRemoteServerPreferred OBJECT-TYPE
    SYNTAX         ToggleValue
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "This object allows server configuration as preferred one on the NTP Remote Server."
    ::= { f3NtpRemoteServerEntry 9 }

f3NtpRemoteServerReach OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "This object returns information on packet loss."
    ::= { f3NtpRemoteServerEntry 10 }

f3NtpRemoteServerStorageType OBJECT-TYPE
    SYNTAX         StorageType
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The type of storage configured for this entry."
    ::= { f3NtpRemoteServerEntry 11 }

f3NtpRemoteServerRowStatus OBJECT-TYPE
    SYNTAX         RowStatus
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION    "The status of this row.  An entry MUST NOT exist in the
        active state unless all objects in the entry have an
        appropriate value, as described
        in the description clause for each writable object.
        
        The values of f3NtpRemoteServerRowStatus supported are
        createAndGo(4) and destroy(6).  All mandatory attributes
        must be specified in a single SNMP SET request with
        f3NtpRemoteServerRowStatus value as createAndGo(4).
        Upon successful row creation, this object has a
        value of active(1).
        
        The f3NtpRemoteServerRowStatus object may be modified if
        the associated instance of this object is equal to active(1)."
    ::= { f3NtpRemoteServerEntry 12 }
--
-- PERFORMANCE 
--
--
-- NTP Clock Interface Statistics Table 
--
f3NCIStatsTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NCIStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection of NTP Clock Interface(NCI) related statistics.
        These reflect the current data."
    ::= { f3NtpPerformanceObjects 1 }

f3NCIStatsEntry OBJECT-TYPE
    SYNTAX         F3NCIStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NCIStatsTable. Entries exist
        in this table for each NTP Clock Interface."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex, f3NCIStatsIndex }
    ::= { f3NCIStatsTable 1 }

F3NCIStatsEntry ::=
    SEQUENCE {
        f3NCIStatsIndex Integer32,
        f3NCIStatsIntervalType CmPmIntervalType,
        f3NCIStatsValid TruthValue,
        f3NCIStatsAction CmPmBinAction,
        f3NCIStatsRequestsProcessed PerfCounter64,
        f3NCIStatsResponsesError PerfCounter64,

        f3NCIStatsAuthFailures  PerfCounter64,
        f3NCIStatsReqsDiscarded PerfCounter64,
        f3NCIStatsAvgTPS        PerfCounter64,
        f3NCIStatsMaxTPS        PerfCounter64
    }


f3NCIStatsIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..4)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this NTP Clock Interface statistics entry.
        1 - 15min
        2 - 1day
        3 - rollover
        4 - 5min"
    ::= { f3NCIStatsEntry 1 }

f3NCIStatsIntervalType OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the type of collection, i.e. whether it is
        15 Min, 1 Day or rollover."
    ::= { f3NCIStatsEntry 2 }

f3NCIStatsValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NCIStatsEntry 3 }

f3NCIStatsAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NCIStatsEntry 4 }

f3NCIStatsRequestsProcessed OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been processed by the NCI."
    ::= { f3NCIStatsEntry 5 }

f3NCIStatsResponsesError OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Error messages that have been transmitted by 
        the NCI when messages could not have been processed."
    ::= { f3NCIStatsEntry 6 }

f3NCIStatsAuthFailures OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Authentication Failures that have been processed by the NCI."
    ::= { f3NCIStatsEntry 7 }

f3NCIStatsReqsDiscarded OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Requests Discarded that have been processed by the NCI."
    ::= { f3NCIStatsEntry 8 }

f3NCIStatsAvgTPS OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Average number of PTS."
    ::= { f3NCIStatsEntry 9 }

f3NCIStatsMaxTPS OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Maximum number of PTS."
    ::= { f3NCIStatsEntry 10 }

--
-- NTP Clock Interface History Table 
--
f3NCIHistoryTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NCIHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection history data for each NTP Clock Interface
        and different time interval."
    ::= { f3NtpPerformanceObjects 2 }

f3NCIHistoryEntry OBJECT-TYPE
    SYNTAX         F3NCIHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NCIHistoryTable.
        Entries exist in this table for each NTP Clock Interface
        and different time interval."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex, f3NCIStatsIndex,
        f3NCIHistoryIndex }
    ::= { f3NCIHistoryTable 1 }

F3NCIHistoryEntry ::=
    SEQUENCE {
        f3NCIHistoryIndex Integer32,
        f3NCIHistoryTime DateAndTime,
        f3NCIHistoryValid TruthValue,
        f3NCIHistoryAction CmPmBinAction,
        f3NCIHistoryRequestsProcessed PerfCounter64,
        f3NCIHistoryResponsesError PerfCounter64,

        f3NCIHistoryAuthFailures  PerfCounter64,
        f3NCIHistoryReqsDiscarded PerfCounter64,
        f3NCIHistoryAvgTPS        PerfCounter64,
        f3NCIHistoryMaxTPS        PerfCounter64
    }


f3NCIHistoryIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..32)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this NTP Clock Interface and time interval entry."
    ::= { f3NCIHistoryEntry 1 }

f3NCIHistoryTime OBJECT-TYPE
    SYNTAX         DateAndTime
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the time of history bin creation."
    ::= { f3NCIHistoryEntry 2 }

f3NCIHistoryValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NCIHistoryEntry 3 }

f3NCIHistoryAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NCIHistoryEntry 4 }

f3NCIHistoryRequestsProcessed OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been processed by the NCI."
    ::= { f3NCIHistoryEntry 5 }

f3NCIHistoryResponsesError OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Error messages that have been transmitted by 
        the NCI when messages could not have been processed."
    ::= { f3NCIHistoryEntry 6 }

f3NCIHistoryAuthFailures OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Authentication Failures that have been processed by the NCI."
    ::= { f3NCIHistoryEntry 7 }

f3NCIHistoryReqsDiscarded OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Requests Discarded that have been processed by the NCI."
    ::= { f3NCIHistoryEntry 8 }

f3NCIHistoryAvgTPS OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Average number of PTS."
    ::= { f3NCIHistoryEntry 9 }

f3NCIHistoryMaxTPS OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP Maximum number of PTS."
    ::= { f3NCIHistoryEntry 10 }

--
-- NTP Clock Interface Threshold Table 
--
f3NCIThresholdTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NCIThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A table of entries that allow manageability of
        a list of Thresholds for NTP Clock Interface."
    ::= { f3NtpPerformanceObjects 3 }

f3NCIThresholdEntry OBJECT-TYPE
    SYNTAX         F3NCIThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NCIThresholdTable."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex, f3NCIStatsIndex,
        f3NCIThresholdIndex }
    ::= { f3NCIThresholdTable 1 }

F3NCIThresholdEntry ::=
    SEQUENCE {
        f3NCIThresholdIndex Integer32,
        f3NCIThresholdInterval CmPmIntervalType,
        f3NCIThresholdVariable VariablePointer,
        f3NCIThresholdValueLo Unsigned32,
        f3NCIThresholdValueHi Unsigned32,
        f3NCIThresholdMonValue PerfCounter64
    }


f3NCIThresholdIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..65535)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An index that uniquely identifies an entry in the
        f3NCIThresholdTable."
    ::= { f3NCIThresholdEntry 1 }

f3NCIThresholdInterval OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The time interval over which monitored value is
        sampled and compared with the specified threshold."
    ::= { f3NCIThresholdEntry 2 }

f3NCIThresholdVariable OBJECT-TYPE
    SYNTAX         VariablePointer
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The object identifier of the particular variable to be sampled."
    ::= { f3NCIThresholdEntry 3 }

f3NCIThresholdValueLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Lower 32 bits of the threshold value."
    ::= { f3NCIThresholdEntry 4 }

f3NCIThresholdValueHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Higher 32 bits of the threshold value."
    ::= { f3NCIThresholdEntry 5 }

f3NCIThresholdMonValue OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Monitored value corresponding to f3NCIThresholdVariable value."
    ::= { f3NCIThresholdEntry 6 }

--
-- Access Port NTP Flow Point Statistics Table 
--
f3NtpAccPortFlowPointStatsTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpAccPortFlowPointStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection of Access Port NTP Flow Point statistics.
        These reflect the current data."
    ::= { f3NtpPerformanceObjects 4 }

f3NtpAccPortFlowPointStatsEntry OBJECT-TYPE
    SYNTAX         F3NtpAccPortFlowPointStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpAccPortFlowPointStatsTable.
        Entries exist in this table for each Access Port NTP Flow Point."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
        f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointStatsIndex }
    ::= { f3NtpAccPortFlowPointStatsTable 1 }

F3NtpAccPortFlowPointStatsEntry ::=
    SEQUENCE {
        f3NtpAccPortFlowPointStatsIndex Integer32,
        f3NtpAccPortFlowPointStatsIntervalType CmPmIntervalType,
        f3NtpAccPortFlowPointStatsValid TruthValue,
        f3NtpAccPortFlowPointStatsAction CmPmBinAction,
        f3NtpAccPortFlowPointStatsRequestsDropped PerfCounter64,
        f3NtpAccPortFlowPointStatsRequestsReceived PerfCounter64,
        f3NtpAccPortFlowPointStatsResponsesTransmitted PerfCounter64
    }


f3NtpAccPortFlowPointStatsIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..4)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this Access Port NTP Flow Point statistics entry.
        1 - 15min
        2 - 1day
        3 - rollover
        4 - 5min"
    ::= { f3NtpAccPortFlowPointStatsEntry 1 }

f3NtpAccPortFlowPointStatsIntervalType OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the type of collection, i.e. whether it is
        5 Min, 15 Min, 1 Day or rollover."
    ::= { f3NtpAccPortFlowPointStatsEntry 2 }

f3NtpAccPortFlowPointStatsValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NtpAccPortFlowPointStatsEntry 3 }

f3NtpAccPortFlowPointStatsAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NtpAccPortFlowPointStatsEntry 4 }

f3NtpAccPortFlowPointStatsRequestsDropped OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been dropped from the NTP Flow Point."
    ::= { f3NtpAccPortFlowPointStatsEntry 5 }

f3NtpAccPortFlowPointStatsRequestsReceived OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been recieved on the NTP Flow Point."
    ::= { f3NtpAccPortFlowPointStatsEntry 6 }

f3NtpAccPortFlowPointStatsResponsesTransmitted OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been transmitted on the NTP Flow Point."
    ::= { f3NtpAccPortFlowPointStatsEntry 7 }

--
-- Access Port NTP Flow Point History Table 
--
f3NtpAccPortFlowPointHistoryTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpAccPortFlowPointHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection of Access Port NTP Flow Point history statistics.
        These reflect the history data."
    ::= { f3NtpPerformanceObjects 5 }

f3NtpAccPortFlowPointHistoryEntry OBJECT-TYPE
    SYNTAX         F3NtpAccPortFlowPointHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpAccPortFlowPointHistoryTable.
        Entries exist in this table for each Access Port Flow Point."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
        f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointStatsIndex,
        f3NtpAccPortFlowPointHistoryIndex }
    ::= { f3NtpAccPortFlowPointHistoryTable 1 }

F3NtpAccPortFlowPointHistoryEntry ::=
    SEQUENCE {
        f3NtpAccPortFlowPointHistoryIndex Integer32,
        f3NtpAccPortFlowPointHistoryTime DateAndTime,
        f3NtpAccPortFlowPointHistoryValid TruthValue,
        f3NtpAccPortFlowPointHistoryAction CmPmBinAction,
        f3NtpAccPortFlowPointHistoryRequestsDropped PerfCounter64,
        f3NtpAccPortFlowPointHistoryRequestsReceived PerfCounter64,
        f3NtpAccPortFlowPointHistoryResponsesTransmitted PerfCounter64
    }


f3NtpAccPortFlowPointHistoryIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..32)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this Ethernet Access Port NTP Flow point history bin entry."
    ::= { f3NtpAccPortFlowPointHistoryEntry 1 }

f3NtpAccPortFlowPointHistoryTime OBJECT-TYPE
    SYNTAX         DateAndTime
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the time of history bin creation."
    ::= { f3NtpAccPortFlowPointHistoryEntry 2 }

f3NtpAccPortFlowPointHistoryValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NtpAccPortFlowPointHistoryEntry 3 }

f3NtpAccPortFlowPointHistoryAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NtpAccPortFlowPointHistoryEntry 4 }

f3NtpAccPortFlowPointHistoryRequestsDropped OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been dropped from the NTP Flow Point."
    ::= { f3NtpAccPortFlowPointHistoryEntry 5 }

f3NtpAccPortFlowPointHistoryRequestsReceived OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been recieved on the NTP Flow Point."
    ::= { f3NtpAccPortFlowPointHistoryEntry 6 }

f3NtpAccPortFlowPointHistoryResponsesTransmitted OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been transmitted on the NTP Flow Point."
    ::= { f3NtpAccPortFlowPointHistoryEntry 7 }

--
-- Access Port NTP Flow Point Threshold Table 
--
f3NtpAccPortFlowPointThresholdTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpAccPortFlowPointThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A table of entries that allow manageability of Access Port NTP Flow Point
        Thresholds."
    ::= { f3NtpPerformanceObjects 6 }

f3NtpAccPortFlowPointThresholdEntry OBJECT-TYPE
    SYNTAX         F3NtpAccPortFlowPointThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpAccPortFlowPointThresholdTable."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
        f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointStatsIndex,
        f3NtpAccPortFlowPointThresholdIndex }
    ::= { f3NtpAccPortFlowPointThresholdTable 1 }

F3NtpAccPortFlowPointThresholdEntry ::=
    SEQUENCE {
        f3NtpAccPortFlowPointThresholdIndex Integer32,
        f3NtpAccPortFlowPointThresholdInterval CmPmIntervalType,
        f3NtpAccPortFlowPointThresholdVariable VariablePointer,
        f3NtpAccPortFlowPointThresholdValueLo Unsigned32,
        f3NtpAccPortFlowPointThresholdValueHi Unsigned32,
        f3NtpAccPortFlowPointThresholdMonValue PerfCounter64
    }


f3NtpAccPortFlowPointThresholdIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..65535)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An index that uniquely identifies an entry in the
        f3NtpAccPortFlowPointThresholdTable."
    ::= { f3NtpAccPortFlowPointThresholdEntry 1 }

f3NtpAccPortFlowPointThresholdInterval OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The interval over which monitored value is
        sampled and compared with the specified threshold."
    ::= { f3NtpAccPortFlowPointThresholdEntry 2 }

f3NtpAccPortFlowPointThresholdVariable OBJECT-TYPE
    SYNTAX         VariablePointer
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The object identifier of the particular variable to be
        sampled."
    ::= { f3NtpAccPortFlowPointThresholdEntry 3 }

f3NtpAccPortFlowPointThresholdValueLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Lower 32 bits of the threshold value."
    ::= { f3NtpAccPortFlowPointThresholdEntry 4 }

f3NtpAccPortFlowPointThresholdValueHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Higher 32 bits of the threshold value."
    ::= { f3NtpAccPortFlowPointThresholdEntry 5 }

f3NtpAccPortFlowPointThresholdMonValue OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Monitored value corresponding to f3NtpAccPortFlowPointThresholdVariable."
    ::= { f3NtpAccPortFlowPointThresholdEntry 6 }

--
-- Network Port NTP Flow Point Statistics Table 
--
f3NtpNetPortFlowPointStatsTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpNetPortFlowPointStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection of Network Port NTP Flow Point statistics.
        These reflect the current data."
    ::= { f3NtpPerformanceObjects 7 }

f3NtpNetPortFlowPointStatsEntry OBJECT-TYPE
    SYNTAX         F3NtpNetPortFlowPointStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpNetPortFlowPointStatsTable.
        Entries exist in this table for each Network Port NTP Flow Point."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
        f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointStatsIndex }
    ::= { f3NtpNetPortFlowPointStatsTable 1 }

F3NtpNetPortFlowPointStatsEntry ::=
    SEQUENCE {
        f3NtpNetPortFlowPointStatsIndex Integer32,
        f3NtpNetPortFlowPointStatsIntervalType CmPmIntervalType,
        f3NtpNetPortFlowPointStatsValid TruthValue,
        f3NtpNetPortFlowPointStatsAction CmPmBinAction,
        f3NtpNetPortFlowPointStatsRequestsDropped PerfCounter64,
        f3NtpNetPortFlowPointStatsRequestsReceived PerfCounter64,
        f3NtpNetPortFlowPointStatsResponsesTransmitted PerfCounter64
    }


f3NtpNetPortFlowPointStatsIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..4)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this Network Port NTP Flow Point statistics entry.
        1 - 15min
        2 - 1day
        3 - rollover
        4 - 5min"
    ::= { f3NtpNetPortFlowPointStatsEntry 1 }

f3NtpNetPortFlowPointStatsIntervalType OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the type of collection, i.e. whether it is
        5 Min, 15 Min, 1 Day or rollover."
    ::= { f3NtpNetPortFlowPointStatsEntry 2 }

f3NtpNetPortFlowPointStatsValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NtpNetPortFlowPointStatsEntry 3 }

f3NtpNetPortFlowPointStatsAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NtpNetPortFlowPointStatsEntry 4 }

f3NtpNetPortFlowPointStatsRequestsDropped OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been dropped from the NTP Flow Point."
    ::= { f3NtpNetPortFlowPointStatsEntry 5 }

f3NtpNetPortFlowPointStatsRequestsReceived OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been recieved on the NTP Flow Point."
    ::= { f3NtpNetPortFlowPointStatsEntry 6 }

f3NtpNetPortFlowPointStatsResponsesTransmitted OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been transmitted on the NTP Flow Point."
    ::= { f3NtpNetPortFlowPointStatsEntry 7 }

--
-- Network Port NTP Flow Point History Table 
--
f3NtpNetPortFlowPointHistoryTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpNetPortFlowPointHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection of Network Port NTP Flow Point history statistics.
        These reflect the history data."
    ::= { f3NtpPerformanceObjects 8 }

f3NtpNetPortFlowPointHistoryEntry OBJECT-TYPE
    SYNTAX         F3NtpNetPortFlowPointHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpNetPortFlowPointHistoryTable.
        Entries exist in this table for each Network Port NTP Flow Point."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
        f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointStatsIndex,
        f3NtpNetPortFlowPointHistoryIndex }
    ::= { f3NtpNetPortFlowPointHistoryTable 1 }

F3NtpNetPortFlowPointHistoryEntry ::=
    SEQUENCE {
        f3NtpNetPortFlowPointHistoryIndex Integer32,
        f3NtpNetPortFlowPointHistoryTime DateAndTime,
        f3NtpNetPortFlowPointHistoryValid TruthValue,
        f3NtpNetPortFlowPointHistoryAction CmPmBinAction,
        f3NtpNetPortFlowPointHistoryRequestsDropped PerfCounter64,
        f3NtpNetPortFlowPointHistoryRequestsReceived PerfCounter64,
        f3NtpNetPortFlowPointHistoryResponsesTransmitted PerfCounter64
    }


f3NtpNetPortFlowPointHistoryIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..32)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this Ethernet Traffic Port NTP Flow point history bin entry."
    ::= { f3NtpNetPortFlowPointHistoryEntry 1 }

f3NtpNetPortFlowPointHistoryTime OBJECT-TYPE
    SYNTAX         DateAndTime
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the time of history bin creation."
    ::= { f3NtpNetPortFlowPointHistoryEntry 2 }

f3NtpNetPortFlowPointHistoryValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NtpNetPortFlowPointHistoryEntry 3 }

f3NtpNetPortFlowPointHistoryAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NtpNetPortFlowPointHistoryEntry 4 }

f3NtpNetPortFlowPointHistoryRequestsDropped OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been dropped from the NTP Flow Point."
    ::= { f3NtpNetPortFlowPointHistoryEntry 5 }

f3NtpNetPortFlowPointHistoryRequestsReceived OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been recieved on the NTP Flow Point."
    ::= { f3NtpNetPortFlowPointHistoryEntry 6 }

f3NtpNetPortFlowPointHistoryResponsesTransmitted OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of NTP messages that have been transmitted on the NTP Flow Point."
    ::= { f3NtpNetPortFlowPointHistoryEntry 7 }

--
-- Network Port NTP Flow Point Threshold Table 
--
f3NtpNetPortFlowPointThresholdTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpNetPortFlowPointThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A table of entries that allow manageability of Network Port NTP Flow Point
        Thresholds."
    ::= { f3NtpPerformanceObjects 9 }

f3NtpNetPortFlowPointThresholdEntry OBJECT-TYPE
    SYNTAX         F3NtpNetPortFlowPointThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpNetPortFlowPointThresholdTable."
    INDEX    { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
        f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointStatsIndex,
        f3NtpNetPortFlowPointThresholdIndex }
    ::= { f3NtpNetPortFlowPointThresholdTable 1 }

F3NtpNetPortFlowPointThresholdEntry ::=
    SEQUENCE {
        f3NtpNetPortFlowPointThresholdIndex Integer32,
        f3NtpNetPortFlowPointThresholdInterval CmPmIntervalType,
        f3NtpNetPortFlowPointThresholdVariable VariablePointer,
        f3NtpNetPortFlowPointThresholdValueLo Unsigned32,
        f3NtpNetPortFlowPointThresholdValueHi Unsigned32,
        f3NtpNetPortFlowPointThresholdMonValue PerfCounter64
    }


f3NtpNetPortFlowPointThresholdIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..65535)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An index that uniquely identifies an entry in the
        f3NtpNetPortFlowPointThresholdTable."
    ::= { f3NtpNetPortFlowPointThresholdEntry 1 }

f3NtpNetPortFlowPointThresholdInterval OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The interval over which monitored value is
        sampled and compared with the specified threshold."
    ::= { f3NtpNetPortFlowPointThresholdEntry 2 }

f3NtpNetPortFlowPointThresholdVariable OBJECT-TYPE
    SYNTAX         VariablePointer
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The object identifier of the particular variable to be
        sampled."
    ::= { f3NtpNetPortFlowPointThresholdEntry 3 }

f3NtpNetPortFlowPointThresholdValueLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Lower 32 bits of the threshold value."
    ::= { f3NtpNetPortFlowPointThresholdEntry 4 }

f3NtpNetPortFlowPointThresholdValueHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Higher 32 bits of the threshold value."
    ::= { f3NtpNetPortFlowPointThresholdEntry 5 }

f3NtpNetPortFlowPointThresholdMonValue OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Monitored value corresponding to f3NtpNetPortFlowPointThresholdVariable."
    ::= { f3NtpNetPortFlowPointThresholdEntry 6 }
    

--
-- PERFORMANCE 
--
--
-- NTP Tracked Client Statistics Table 
--
f3NtpTrackedClientStatsTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpTrackedClientStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection of NTP Tracked Client related statistics.
        These reflect the current data."
    ::= { f3NtpPerformanceObjects 10 }

f3NtpTrackedClientStatsEntry OBJECT-TYPE
    SYNTAX         F3NtpTrackedClientStatsEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpTrackedClientStatsTable. Entries exist
        in this table for each NTP Tracked Client."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex, f3NtpTrackedClientStatsClientIndex, 
    f3NtpTrackedClientStatsIndex }
    ::= { f3NtpTrackedClientStatsTable 1 }

F3NtpTrackedClientStatsEntry ::=
    SEQUENCE {
        f3NtpTrackedClientStatsIndex Integer32,
        f3NtpTrackedClientStatsClientIndex Integer32,
        f3NtpTrackedClientStatsIntervalType CmPmIntervalType,
        f3NtpTrackedClientStatsValid TruthValue,
        f3NtpTrackedClientStatsAction CmPmBinAction,
        f3NtpTrackedClientStatsResponsesTransmitted PerfCounter64,
        f3NtpTrackedClientStatsRequestsReceived PerfCounter64      
    }


f3NtpTrackedClientStatsIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..4)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this NTP Tracked Client statistics entry.
        1 - 15min
        2 - 1day
        3 - rollover
        4 - 5min"
    ::= { f3NtpTrackedClientStatsEntry 1 }
    

f3NtpTrackedClientStatsClientIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..4)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this NTP Tracked Client ."
    ::= { f3NtpTrackedClientStatsEntry 2 }

f3NtpTrackedClientStatsIntervalType OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the type of collection, i.e. whether it is
        15 Min, 1 Day or rollover."
    ::= { f3NtpTrackedClientStatsEntry 3 }

f3NtpTrackedClientStatsValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NtpTrackedClientStatsEntry 4 }

f3NtpTrackedClientStatsAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NtpTrackedClientStatsEntry 5 }

f3NtpTrackedClientStatsResponsesTransmitted OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of messages that have been transmitted by the Ntp Tracked Client."
    ::= { f3NtpTrackedClientStatsEntry 6 }

f3NtpTrackedClientStatsRequestsReceived OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of requests messages that have been received by the NtpTrackedClient."
    ::= { f3NtpTrackedClientStatsEntry 7 }


--
-- NTP Tracked Client History Table 
--
f3NtpTrackedClientHistoryTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpTrackedClientHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A collection history data for each NTP Tracked Client
        and different time interval."
    ::= { f3NtpPerformanceObjects 11 }

f3NtpTrackedClientHistoryEntry OBJECT-TYPE
    SYNTAX         F3NtpTrackedClientHistoryEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpTrackedClientHistoryTable.
        Entries exist in this table for each NTP Tracked Client
        and different time interval."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex, f3NtpTrackedClientStatsClientIndex, 
    		f3NtpTrackedClientStatsIndex, f3NtpTrackedClientHistoryIndex }
    ::= { f3NtpTrackedClientHistoryTable 1 }

F3NtpTrackedClientHistoryEntry ::=
    SEQUENCE {
        f3NtpTrackedClientHistoryIndex Integer32,
        f3NtpTrackedClientHistoryTime DateAndTime,
        f3NtpTrackedClientHistoryValid TruthValue,
        f3NtpTrackedClientHistoryAction CmPmBinAction,       
        f3NtpTrackedClientHistoryResponsesTransmitted PerfCounter64,
        f3NtpTrackedClientHistoryRequestsReceived PerfCounter64

    }


f3NtpTrackedClientHistoryIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..32)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An arbitrary integer index value used to uniquely identify
        this NTP Tracked Client and time interval entry."
    ::= { f3NtpTrackedClientHistoryEntry 1 }

f3NtpTrackedClientHistoryTime OBJECT-TYPE
    SYNTAX         DateAndTime
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the time of history bin creation."
    ::= { f3NtpTrackedClientHistoryEntry 2 }

f3NtpTrackedClientHistoryValid OBJECT-TYPE
    SYNTAX         TruthValue
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Indicates the validity of the bin."
    ::= { f3NtpTrackedClientHistoryEntry 3 }

f3NtpTrackedClientHistoryAction OBJECT-TYPE
    SYNTAX         CmPmBinAction
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Allows the Manager to clear the bin."
    ::= { f3NtpTrackedClientHistoryEntry 4 }

f3NtpTrackedClientHistoryResponsesTransmitted OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of responses that have been transmitted."
    ::= { f3NtpTrackedClientHistoryEntry 5 }

f3NtpTrackedClientHistoryRequestsReceived OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Count of requests that have been received."
    ::= { f3NtpTrackedClientHistoryEntry 6 }

--
-- NTP Tracked Client Threshold Table 
--
f3NtpTrackedClientThresholdTable OBJECT-TYPE
    SYNTAX         SEQUENCE OF F3NtpTrackedClientThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A table of entries that allow manageability of
        a list of Thresholds for NTP Tracked Client."
    ::= { f3NtpPerformanceObjects 12 }

f3NtpTrackedClientThresholdEntry OBJECT-TYPE
    SYNTAX         F3NtpTrackedClientThresholdEntry
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "A conceptual row in the f3NtpTrackedClientThresholdTable."
    INDEX    { neIndex, f3NtpClockIndex, f3NCIIndex, f3NtpTrackedClientStatsClientIndex,
    		f3NtpTrackedClientStatsIndex, f3NtpTrackedClientThresholdIndex }
    ::= { f3NtpTrackedClientThresholdTable 1 }

F3NtpTrackedClientThresholdEntry ::=
    SEQUENCE {
        f3NtpTrackedClientThresholdIndex Integer32,
        f3NtpTrackedClientThresholdInterval CmPmIntervalType,
        f3NtpTrackedClientThresholdVariable VariablePointer,
        f3NtpTrackedClientThresholdValueLo Unsigned32,
        f3NtpTrackedClientThresholdValueHi Unsigned32,
        f3NtpTrackedClientThresholdMonValue PerfCounter64
    }


f3NtpTrackedClientThresholdIndex OBJECT-TYPE
    SYNTAX         Integer32 (1..65535)
    MAX-ACCESS     not-accessible
    STATUS         current
    DESCRIPTION    "An index that uniquely identifies an entry in the
        f3NtpTrackedClientThresholdTable."
    ::= { f3NtpTrackedClientThresholdEntry 1 }

f3NtpTrackedClientThresholdInterval OBJECT-TYPE
    SYNTAX         CmPmIntervalType
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The time interval over which monitored value is
        sampled and compared with the specified threshold."
    ::= { f3NtpTrackedClientThresholdEntry 2 }

f3NtpTrackedClientThresholdVariable OBJECT-TYPE
    SYNTAX         VariablePointer
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "The object identifier of the particular variable to be sampled."
    ::= { f3NtpTrackedClientThresholdEntry 3 }

f3NtpTrackedClientThresholdValueLo OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Lower 32 bits of the threshold value."
    ::= { f3NtpTrackedClientThresholdEntry 4 }

f3NtpTrackedClientThresholdValueHi OBJECT-TYPE
    SYNTAX         Unsigned32
    MAX-ACCESS     read-write
    STATUS         current
    DESCRIPTION    "Higher 32 bits of the threshold value."
    ::= { f3NtpTrackedClientThresholdEntry 5 }

f3NtpTrackedClientThresholdMonValue OBJECT-TYPE
    SYNTAX         PerfCounter64
    MAX-ACCESS     read-only
    STATUS         current
    DESCRIPTION    "Monitored value corresponding to f3NtpTrackedClientThresholdVariable value."
    ::= { f3NtpTrackedClientThresholdEntry 6 }


f3NtpTrackedClientCrossingAlert NOTIFICATION-TYPE
    OBJECTS {
        f3NtpTrackedClientThresholdIndex,
        f3NtpTrackedClientThresholdInterval,
        f3NtpTrackedClientThresholdVariable,
        f3NtpTrackedClientThresholdValueLo,
        f3NtpTrackedClientThresholdValueHi,
        f3NtpTrackedClientThresholdMonValue
    }
    STATUS  current
    DESCRIPTION
            "This trap is sent each time a threshold on a PM condition
             on an NtpTrackedClient is crossed."
  ::= { f3NtpPerformanceNotifications 1 }


--
-- Conformance
--
f3NtpCompliances OBJECT IDENTIFIER ::= {f3NtpConformance 1}
f3NtpGroups      OBJECT IDENTIFIER ::= {f3NtpConformance 2}

f3NtpCompliance MODULE-COMPLIANCE
    STATUS         current
    DESCRIPTION    "Describes the requirements for conformance to the F3 NTP
        group."
    MODULE    -- this module
        MANDATORY-GROUPS {
              f3NtpObjectGroup, f3NtpPerfObjectGroup
        }

    ::= { f3NtpCompliances 1 }


f3NtpObjectGroup OBJECT-GROUP
    OBJECTS    {
        f3NtpClockIndex, f3NtpClockAlias,
        f3NtpClockAdminState, f3NtpClockOperationalState,
        f3NtpClockTimeClock, f3NtpClockStratumLevel,
        f3NtpClockLeapIndicator, f3NtpClockTimeScale,
        f3NtpClockPrecision, f3NtpClockRootDelay,
        f3NtpClockRootDispersion, f3NtpClockNtpMode,
        f3NtpClockNtpType, f3NtpClockNtpAuthentication,
        f3NtpClockServerState, f3NtpClockTimeReferenceLossHandling,
        f3NtpClockRefClockId, f3NtpClockStorageType, f3NtpClockRowStatus,
	f3NtpAuthenticationSecureMode,f3NtpAutokeyCtrl, f3NtpClockOffset, f3NtpClockSecondaryState,
        
        f3NCIIndex, f3NCIAlias,
        f3NCIAdminState, f3NCIOperationalState,
        f3NCIIfName, f3NCIIpProtocol,
        f3NCIIpV4Address, f3NCIIpV4SubnetMask,
        f3NCIDscp, f3NCIStorageType, f3NCIRowStatus,
        f3NCIIpV6UdpChecksum, f3NCIIpV6Address,
        f3NCIIpV6AddrPrefixLength, f3NCIIpV4Gateway,
        f3NCIIpV6Gateway,f3NCIDefaultGatewayControl,
        f3NCIDaytimeServiceControl, f3NCITimeServiceControl,
        
        f3NCIBroadcastState, f3NCIBroadcastIpV4Address,
        f3NCIBroadcastIpV6Address, f3NCIBroadcastInterval,
        f3NCIBroadcastMaxHops, f3NCIBroadcastSymKeyId,
        f3NCIBroadcastNtpVersion,
        f3NCIAssociationMode, f3NCIPeer1IpV4Address,
        f3NCIPeer2IpV4Address, f3NCIPeer3IpV4Address,
        f3NCIPeer1IpV6Address, f3NCIPeer2IpV6Address,
        f3NCIPeer3IpV6Address, f3NCIPeerMinInterval,
        f3NCIPeerMaxInterval, f3NCIPeerSymKeyIdList,
        f3NCITimeScale, f3NCICurrentTimeOfDay,
        f3NCINtpHardenedResponderControl,
               
        f3NtpVirtualPortIndex, f3NtpVirtualPortAlias,
        f3NtpVirtualPortAdminState, f3NtpVirtualPortOperationalState,
        f3NtpVirtualPortNtpFlowPoint,
        f3NtpVirtualPortStorageType, f3NtpVirtualPortRowStatus,
        
        f3NtpRemoteClientIndex, f3NtpRemoteClientIpV4Address,
        f3NtpRemoteClientRxPackets, f3NtpRemoteClientAvgPollInterval,
        f3NtpRemoteClientLastPollInterval, f3NtpRemoteClientNtpMode,
        f3NtpRemoteClientNtpVersion, f3NtpRemoteClientStorageType,
        f3NtpRemoteClientRowStatus,
        
        f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointAlias,
        f3NtpAccPortFlowPointAdminState, f3NtpAccPortFlowPointOperationalState,
        f3NtpAccPortFlowPointType,
        f3NtpAccPortFlowPointOuterVlanEtherType, f3NtpAccPortFlowPointOuterVlanMemberList,
        f3NtpAccPortFlowPointOuterUntaggedEnabled, f3NtpAccPortFlowPointInner1VlanEtherType,
        f3NtpAccPortFlowPointInner1VlanMemberList, f3NtpAccPortFlowPointInner1UntaggedEnabled,
        f3NtpAccPortFlowPointInner2VlanEtherType, f3NtpAccPortFlowPointInner2VlanMemberList,
        f3NtpAccPortFlowPointInner2UntaggedEnabled, f3NtpAccPortFlowPointCOS,
        f3NtpAccPortFlowPointCIRLo, f3NtpAccPortFlowPointCIRHi,
        f3NtpAccPortFlowPointEIRLo, f3NtpAccPortFlowPointEIRHi,
        f3NtpAccPortFlowPointBufferSize, f3NtpAccPortFlowPointStorageType, f3NtpAccPortFlowPointRowStatus,
        
        f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointAlias,
        f3NtpNetPortFlowPointAdminState, f3NtpNetPortFlowPointOperationalState,
        f3NtpNetPortFlowPointType,
        f3NtpNetPortFlowPointOuterVlanEtherType, f3NtpNetPortFlowPointOuterVlanMemberList,
        f3NtpNetPortFlowPointOuterUntaggedEnabled, f3NtpNetPortFlowPointInner1VlanEtherType,
        f3NtpNetPortFlowPointInner1VlanMemberList, f3NtpNetPortFlowPointInner1UntaggedEnabled,
        f3NtpNetPortFlowPointInner2VlanEtherType, f3NtpNetPortFlowPointInner2VlanMemberList,
        f3NtpNetPortFlowPointInner2UntaggedEnabled, f3NtpNetPortFlowPointCOS,
        f3NtpNetPortFlowPointCIRLo, f3NtpNetPortFlowPointCIRHi,
        f3NtpNetPortFlowPointEIRLo, f3NtpNetPortFlowPointEIRHi,
        f3NtpNetPortFlowPointBufferSize, f3NtpNetPortFlowPointStorageType, f3NtpNetPortFlowPointRowStatus,
        
        f3NtpTrackedClientIndex, f3NtpTrackedClientAlias, 
        f3NtpTrackedClientIpV4Address, f3NtpTrackedClientIpV6Address,
        f3NtpTrackedClientStorageType, f3NtpTrackedClientRowStatus,
        f3NtpRemoteServerIndex, f3NtpRemoteServerAlias, f3NtpRemoteServerAdminState,
        f3NtpRemoteServerOperationalState, f3NtpRemoteServerServerAddress,       
        f3NtpRemoteServerMinPollInterval, f3NtpRemoteServerMaxPollInterval,
        f3NtpRemoteServerPreferred, f3NtpRemoteServerReach,                                      
        f3NtpRemoteServerStorageType, f3NtpRemoteServerRowStatus
               
        }
    STATUS         current
    DESCRIPTION    "A collection of objects used to manage the F3 NTP Object group."
    ::= { f3NtpGroups 1 }

f3NtpPerfObjectGroup OBJECT-GROUP
    OBJECTS {

        f3NCIStatsIndex, f3NCIStatsIntervalType,
        f3NCIStatsValid, f3NCIStatsAction,
        f3NCIStatsRequestsProcessed, f3NCIStatsResponsesError,
        f3NCIStatsAuthFailures, 
        f3NCIStatsReqsDiscarded,
        f3NCIStatsAvgTPS,       
        f3NCIStatsMaxTPS,       

        f3NCIHistoryIndex, f3NCIHistoryTime,
        f3NCIHistoryValid, f3NCIHistoryAction,
        f3NCIHistoryRequestsProcessed, f3NCIHistoryResponsesError,
        f3NCIHistoryAuthFailures, 
        f3NCIHistoryReqsDiscarded,
        f3NCIHistoryAvgTPS,       
        f3NCIHistoryMaxTPS,       

        f3NCIThresholdIndex, f3NCIThresholdInterval,
        f3NCIThresholdVariable, f3NCIThresholdValueLo,
        f3NCIThresholdValueHi, f3NCIThresholdMonValue,

        f3NtpAccPortFlowPointStatsIndex, f3NtpAccPortFlowPointStatsIntervalType,
        f3NtpAccPortFlowPointStatsValid, f3NtpAccPortFlowPointStatsAction,
        f3NtpAccPortFlowPointStatsRequestsDropped,
        f3NtpAccPortFlowPointStatsRequestsReceived, f3NtpAccPortFlowPointStatsResponsesTransmitted,

        f3NtpAccPortFlowPointHistoryIndex, f3NtpAccPortFlowPointHistoryTime,
        f3NtpAccPortFlowPointHistoryValid, f3NtpAccPortFlowPointHistoryAction,
        f3NtpAccPortFlowPointHistoryRequestsDropped,
        f3NtpAccPortFlowPointHistoryRequestsReceived, f3NtpAccPortFlowPointHistoryResponsesTransmitted,

        f3NtpAccPortFlowPointThresholdIndex, f3NtpAccPortFlowPointThresholdInterval,
        f3NtpAccPortFlowPointThresholdVariable,
        f3NtpAccPortFlowPointThresholdValueLo, f3NtpAccPortFlowPointThresholdValueHi,
        f3NtpAccPortFlowPointThresholdMonValue,
       
        f3NtpNetPortFlowPointStatsIndex, f3NtpNetPortFlowPointStatsIntervalType,
        f3NtpNetPortFlowPointStatsValid, f3NtpNetPortFlowPointStatsAction,
        f3NtpNetPortFlowPointStatsRequestsDropped,
        f3NtpNetPortFlowPointStatsRequestsReceived, f3NtpNetPortFlowPointStatsResponsesTransmitted,

        f3NtpNetPortFlowPointHistoryIndex, f3NtpNetPortFlowPointHistoryTime,
        f3NtpNetPortFlowPointHistoryValid, f3NtpNetPortFlowPointHistoryAction,
        f3NtpNetPortFlowPointHistoryRequestsDropped,
        f3NtpNetPortFlowPointHistoryRequestsReceived, f3NtpNetPortFlowPointHistoryResponsesTransmitted,

        f3NtpNetPortFlowPointThresholdIndex, f3NtpNetPortFlowPointThresholdInterval,
        f3NtpNetPortFlowPointThresholdVariable,
        f3NtpNetPortFlowPointThresholdValueLo, f3NtpNetPortFlowPointThresholdValueHi,
        f3NtpNetPortFlowPointThresholdMonValue,
        
        f3NtpTrackedClientStatsIndex, f3NtpTrackedClientStatsIntervalType,
        f3NtpTrackedClientStatsValid, f3NtpTrackedClientStatsAction,
        f3NtpTrackedClientStatsResponsesTransmitted, f3NtpTrackedClientStatsRequestsReceived,
              

        f3NtpTrackedClientHistoryIndex, f3NtpTrackedClientHistoryTime,
        f3NtpTrackedClientHistoryValid, f3NtpTrackedClientHistoryAction,
        f3NtpTrackedClientHistoryResponsesTransmitted, f3NtpTrackedClientHistoryRequestsReceived,
            

        f3NtpTrackedClientThresholdIndex, f3NtpTrackedClientThresholdInterval,
        f3NtpTrackedClientThresholdVariable, f3NtpTrackedClientThresholdValueLo,
        f3NtpTrackedClientThresholdValueHi, f3NtpTrackedClientThresholdMonValue     
        


    }
    STATUS  current
    DESCRIPTION
        "A collection of objects used to manage the F3 NTP Performance data."
    ::= { f3NtpGroups 2 }

END